EuroSystem ES TFC2 Release-4 Technology
There was a time when those who wanted to benefit from
the use of Reverse Osmosis (“RO”) technology
had to take a quick course in physics to understand
their system’s operation. We changed all that
back in 1992. In fact, the introduction of the first
EuroSystem products using proprietary technology caused
industry heavyweights to go back and reexamine their
engineering benchmarks for effective RO purification.
Although the product line has indeed received refinements
since that of the first generation units, one thing
still remains certain today; EuroSystem has indisputably
held its position as the benchmark in the industry for
unmatched superiority in performance and ease-of-use.
Our latest EuroSystem Technology “ES TFC2 Release-4”
remains unparalleled—typically delivering twice
the performance in half the space of its counterparts.
Reverse osmosis performance can only be as good as
the membrane technology it employs. A membrane’s
superiority or inferiority will directly affect a system’s
rejection rate against challenge contaminates (separation
effectiveness or quality) as well as its product production
rate (capacity or yield). That’s why we invented
early TFC2 technology back in 1986. Our ES TFC2™
membrane is made of a proprietary Thin-Film C2 composite
that offers greater structural stability and increased
chemical tolerance; it operates more effectively at
lower pressures and delivers a higher quality yield
faster than its counterparts, even when challenged in
highly contaminated brackish water environments. It
is precisely such problematic areas where EuroSystem
Technology remains at the helm today, benefiting companies
worldwide. ES series system performance specifications
remain far above industry standards, in most cases double
that of standard run-of-the-mill RO. The ability to
operate effectively in higher contaminated environments
is a demonstration of its superiority over others in
its category.
Why Reverse Osmosis?
Reverse Osmosis (“RO”) is a membrane separation
technology capable of removing a broad range of contaminants:
sodium, nitrates, toxic metals, arsenic, lead, mercury,
aluminum, pesticides, herbicides, trihalomethanes, bacteria,
radioactive substances and much more. RO purification
and simple water filtration are not the same. Basic
filters are only able to trap and store a few basic
impurities at best, whereas RO purification is able
to produce high-purity water low in Total Dissolved
Solids (‘TDS”) even in adverse environments.
Simply no other technology can remove the broad spectrum
of contaminants and deliver the overall water purity
and taste of a RO system. Today, reverse osmosis separation
technology is so effective some major bottle water brands
use the method for processing the bottle water they
deliver at a premium cost.
Facts
about drinking water
Why EuroSystem purification is used by some
of the biggest names
Straightforward interface. Systems
are fully automatic—eliminating all the unnecessary
knobs, buttons, gadgets or interaction required from
the end-user. Features glycerin filled gauges for consistent
accurate readings with shock and pulsation protection.
Expandable ready. By use of expandable
760 Membrane Kits, production can be increased in a
snap; just clip-on a module and you’ve increased
the production capacity of your system. This extraordinary
feature means the system can grow as your needs grow
for more pure water in the future.
Membrane ES TFC2™ (Release-4).
Made of an exclusive Thin-Film C2 aromatic polyamide
composite ND, offers higher rejection, greater structural
stability and operates more effectively at lower pressures.
EuroSystem ES TFC2 Release-4 Technology remains unparalleled—typically
delivering twice the performance in half the space of
its counterparts.
Auto cleaning cycle. Self-cleans automatically
by a special flow design that actually scrubs the surface
of the membrane; enables longer membrane life, higher
levels of recovery and unparalleled levels of rejection.
Standby operation. ES series systems
offer precise reservoir level detection; the system
will operate any time a low reservoir level is detected
and interfaces with any type of pressurized (hydro pneumatic)
or static (atmospheric) storage reservoir.
Low pressure protection. Low pressure
sensor protects the pump and overall system components
from low pressure, cavitations and overheating.
Bypass protection. Protects the system
and storage reservoir from over-pressure damage. If
over-pressure is detected, a bypass valve will divert
the overload back to the low pressure feed circuit.
An essential feature overlooked on most systems.
Thermal protection. A thermal sensing
device with automatic reset for overall system protection
from excessive ambient temperatures.
High-pressure HB pump. Developed specifically
for the ES series commercial system; made of special
materials highly resistant to corrosion; powerful, quiet
and reliable, coupled with a continuous duty motor.
Pressure connectors. Made of extruded
solid brass series CA-300 with sleeves made of Acetal
Copolymer Celcon capable of operating under continuous
high pressures.
Special materials. US-FDA compliant
and/or US-NSF listed. All wetted parts are made with
materials approved for use with water intended for human
consumption. Even the outer chassis is stainless steel
and a standard feature on all ES series models; essential
for installations in problematical environments.
Options, accessories and related products
FilterPac. Pre-treatment filtration
is critical to system performance. The FilterPac provides
complete system protection with minimal frequency of
maintenance. Pre and post-treatment FilterPacs are available
along with a variety of filter cartridge possibilities,
from system feed protection to pure water post-treatment.
760 Membrane Kit. Expandable module
just snaps-on; increases the production of the system
in increments of 760 liters per day; designed for quick
and easy installation.
UltraV. High performance Ultraviolet
(UV) module for pure processed water made of all non-corrosive
materials; available in various sizes from as little
as 3.8 liter/minute flow.
Optional series SS. System models
with the “SS” prefix include stainless steel
and nickel plated components; recommended for fluid
environments exceeding 2500 mg/liter Total Dissolved
Solids (“TDS”).
Storage vessels. Hydro pneumatic storage
reservoirs designed specifically for pure processed
water made of non-corrosive materials; quick and easy
to install and available in four sizes: 12, 75, 150
or 300 liter capacities. All sizes discharge completely
in any position and are serviceable by a removable water
cell.
Special LR Faucets. Optional faucets
recommended for commercial applications or anywhere
a faucet installation requires additional distance from
a sink or filling large containers. Incorporates two
smooth handle positions: intermittent or continuous
open flow; easy to install anywhere and serviceable
by replaceable valve kit.
True graded density Pre-filtration.
Thermally bonded bi-component fiber cartridges in true
graded density, available in nominal ratings of 1, 5,
25 or 50 micron; removes sediment and rust better than
conventional types found in most commercial systems;
benefits are longer cartridge life, less frequent service
and better overall system protection.
Special media cartridges. Using proprietary
blends of activated KDF and silver impregnated carbons,
more effective in removing chlorine, chloramines, volatile
organic compounds (VOC), chlorinated hydrocarbons and
other contaminants; provides superior protection for
the life of TFC2™ membranes as well as excellent
post-treatment performance.
Post-filtration TCR. Toxic Contaminant
Removal, additional protection for the final post-treatment,
contains special activated carbon to significantly reduce
high levels of organic chemicals, dissolved gasses and
unpleasant tastes and odors.
Worldwide support. A full range of
special products from chemical testing equipment, special
tools, membrane cleaning chemicals as well as standard
service cartridges and replacement parts are available
worldwide from various fulfillment centers—fast.
Technical specifications (EuroSystem ES series
model 1.5 and smaller)
Applications
EuroSystem commercial ES series purification is recommended
for restaurants, hotels, schools, food service operations,
including feed water for ice and coffee machines, food
processing as ingredient water or rinse water, industrial
applications such as green house watering systems, steam
equipment, humidifiers, all types of spot-free rinsing
including the electronic industry, medical and pharmaceutical
laboratories, or simply anywhere pure water is required.
Production Capacity (in Liters) 1
| |
Day |
Hour |
Minute |
| Model 195 |
195 |
8.13 |
0.14 |
| Model 380 |
380 |
15.83 |
0.26 |
| Model 760 |
760 |
31.67 |
0.53 |
| Model 1.1 |
1140 |
47.50 |
0.79 |
| Model 1.5 2 |
1520 |
63.33 |
1.06 |
Characteristics
Process: Reverse Osmosis (UV optional)
Number of phases: varies, depending on configuration
Membrane: ES TFC2™ (Release-4) Thin-Film C2 aromatic
polyamide composite
Recovery: 10 to 50% (adjustable) 3
Rejection (separation) 97% average (90% nominal)
Service frequency: varies, depending on the FilterPac
and cartridge configuration
Operating Environment Parameters
Temperature fluid: 3 degrees C min., 45 degrees C max.
PH continuous operation: 4 min. 11 max.
PH short term cleaning: 2 min., 12 max. (60 minutes)
Iron: 0.10 mg/liter (dissolved) 4
Manganese: 0.05 mg/liter 4
Free chlorine: 1.00 mg/liter 4
Hydrogen sulfide: 0.00 mg/liter
Organics: 1.00 mg/liter 4
Total hardness: 360 mg/liter (PH 7.0) 4
Silt density index (SDI): 5.00 maximum (15 minutes)
Total Dissolved Solids (“TDS”): 2500 mg/liter
(system Version 1) 4
Total Dissolved Solids (“TDS”): 7000 mg/liter
(system Version 2) 4
Feed water flow: 9500 ml/minute (at 1.5 Kg/cm2) 5 Feed
water supply pressure: 1.5 min., 7.0 max. Kg/cm2 (Bar)
5
Electrical requirements
Volts /Amps
230. VAC /3.1 amps (model group 22)
115. VAC /6.2 amps (model group 11)
Hertz: 50 or 60 Hz.
Phase: single phase Duty cycle: continuous
Dimensions and weight:
Gross weight Processor: 45 lbs (20.5 kg) including
all packaging
Dimensions Processor: height 10.75” width 16.5”
depth 8.5” (275mm x 420mm x 215mm)
EuroSystem ES series commercial systems are completely
assembled, factory tested and ready to operate.
Warranty
ES series systems are warranted against defects in
materials and workmanship for a period of one year.
The membrane is covered for manufacturing defects for
the period of one year on a pro-rated basis. Disposable
cartridges are not warranted.
EuroSystem
warranty information
Ordering information (system models available)
7
SYSTEM 195/A/TFC 9001.2332
SYSTEM 195/A/TFC/B 9002.2332
SYSTEM 195/A/TFC/SS 9001.2333
SYSTEM 195/A/TFC/SS/B 9002.2333
SYSTEM 380/A/TFC 9001.2434
SYSTEM 380/A/TFC/B 9002.2434
SYSTEM 380/A/TFC/SS 9001.2435
SYSTEM 380/A/TFC/SS/B 9002.2435
SYSTEM 760/A/TFC 9101.2636
SYSTEM 760/A/TFC/B 9102.2636
SYSTEM 760/A/TFC/SS 9101.2637
SYSTEM 760/A/TFC/SS/B 9102.2637
SYSTEM 1.1/A/TFC 9201.2638
SYSTEM 1.1/A/TFC/B 9202.2638
SYSTEM 1.1/A/TFC/SS 9201.2639
SYSTEM 1.1/A/TFC/SS/B 9202.2639
SYSTEM 1.5/A/TFC 9201.2642
SYSTEM 1.5/A/TFC/B 9202.2642
SYSTEM 1.5/A/TFC/SS 9201.2643
SYSTEM 1.5/A/TFC/SS/B 9202.2643
Ordering information (related products) 8
FILTERPAC 2 PRE 9001.2017
FILTERPAC 2 CARBON 9001.2018
ULTRAVPAC 7.6/230 /V 9201.2026
ULTRAVPAC 7.6/115 /V 9201.2028
ULTRAV 3.8/H/230 /S 9201.2011
ULTRAV 3.8/H/115 /S 9201.2013
ULTRAV 7.6/L/230/30/V 9202.2016
ULTRAV 7.6/L/115/30/V 9202.2018
ULTRAV 7.6/H/230 /S 9201.2015
ULTRAV 7.6/H/115 /S 9201.2017
PART INSERT/FEED/4/8 9001.3051
PART UNION /FEED/4/6 9001.3052
PART EXTENSION/FAUCET 9001.3025
PART KIT/MEMB/380/TFC 9131.5009
PART KIT/MEMB/760/TFC 9131.5001
PART RESERVOIR / 12L 9001.5015
PART RESERVOIR / 75L 9001.5036
PART RESERVOIR /150L 9001.5038
PART RESERVOIR /300L 9001.5039
ULTRAHOT/1.9/HC/115V/0 9602.2702
PART DISPENSER/11/DK3 9202.5024
PART FAUCET/SM/CROME 9001.5019
PART FAUCET/SM/COLOR 9002.5019
PART FAUCET/LR/CROME 9102.5019
PART FAUCET/DUAL/CROME 9601.5019
PART HOUSING/25/ 4/BL 9021.5090
PART HOUSING/25/ 4/CL 9021.5008
PART HOUSING/25/12/BL 9001.5090
PART HOUSING/50/12/BL 9061.5098
Service cartridges 8
PART FILTER/PRE/ 1M 9001.4096
PART FILTER/PRE/ 5M 9001.4007
PART FILTER/PRE/25M 9001.4097
PART FILTER/PRE/50M 9101.4001
PART FILTER/PRE/CAL 9001.4009
PART FILTER/CAL/25 9001.4047
PART FILTER/CARBON 9001.4008
PART FILTER/CARB/50 9101.4050
PART FILTER/CARB/75 9101.4075
PART FILTER/CARB/150 9101.4052
PART FILTER/CARB/EX 9101.4051
PART FILTER/CARB/1M2 9101.4055
PART FILTER/CARB/5M2 9101.4059
PART FILTER/CAL/10/4 9001.4046
PART FILTER/TCR/10/4 9001.4011
PART CHLORINAT/30/4/P 9131.4002
PART MEMBRANE/ 51/CE 9001.4214
PART MEMBRANE/ 51/TFC 9001.4211
PART MEMBRANE/195/TFC 9001.4312
PART MEMBRANE/380/TFC 9001.4413
PART MEMBRANE/760/TFC 9101.4615
PART MEMBRANE/1.1/TFC 9101.4617
PART MEMBRANE/1.5/TFC 9101.4619
Testing instruments 8
TEST METER/PO/PH 9001.8002
TEST METER/PO/TEMP 9001.8003
TEST METER/PO/TDS/10 9001.8001
TEST METER/PO/TDS/100 9102.8001
Other related products
Footnotes *
1. Based on 250 mg/liter Total Dissolved Solids (“TDS”)
or NaCI at 25 degrees C (77 degrees F), feed pressure
2.5 Kg/cm2 (36.PSI). Performance of the reverse osmosis
membrane element is affected by net driving pressure,
feed water temperature, TDS and local water chemistry.
These factors must be taken into account when comparing
or evaluating the performance of a membrane element
or reverse osmosis system. For production capacity in
gallons divide by 3.785.
2. System model 1.5 is available for environments where
the TDS does not exceed 1000 mg/liter.
3. System recovery is factory pre-set; adjustments
remain possible on all models. Actual recovery performance
is influenced by feed water temperature, TDS and local
water chemistry.
4. Recommended for maximum life of the membrane. Pre-treatment
filtration is required upstream prior to the processor
by using a FilterPac(s) with the appropriate cartridges.
If the source is a private well, a complete water analysis
should be evaluated to determine proper pre-treatment.
5. For installations where feed water flow and/or feed
water pressure is insufficient, a pump (booster) with
separate reservoir is recommended upstream prior to
the system.
6. TFC2 and ES TFC2 membrane is a registered trademark
of EuroSystem Systems & Technology, a subsidiary
of Carelli International Corporation USA.
7. The installation and operation of our ES series
commercial systems is surprisingly quick and easy. Systems
are completely assembled, factory tested, and ready
to operate. Systems include an easy to understand installation/operation
manual.
8. Only a partial list of related products. Check with
your local EuroSystem reseller for more specific details
on system options and related products.
Legal information
© 1986-2012 Carelli International Corporation.
All Rights Reserved. EuroSys, EuroSystem, the EuroSystem
logo, TFC2 Membrane, ES TFC2 Membrane, FilterPac, UltraV,
and other product names, model numbers, logos, commercial
symbols, trade names and slogans are trademarks of Carelli
International Corporation or its subsidiaries in the
U.S. and other countries. Products are U.S. patent pending.
© 1973-2012 Carelli International Corporation.
All Rights Reserved. Carelli, Carelli Design, Vittorio
Carelli, and the Carelli logo are registered trademarks
of Carelli International Corporation or its subsidiaries
in the U.S. and other countries.
We reserve the right of modification to materials,
system design and or specifications without prior notice.
Mention of non-EuroSystem products is for informational
purposes and constitutes neither an endorsement nor
a recommendation. Carelli International Corporation
assumes no responsibility with regard to the selection,
performance, or use of these products.
Revised January 2012
Publication Ref. 9242.9461 EN form 9461.1/V718
|